WINCO AUTOMATIC TRANSFER SWITCH ASCO 185 Series, AMPS/100, 200, 400NEMA1-SE Rated, 1Ph
WINCO AUTOMATIC TRANSFER SWITCH ASCO 185 Series, AMPS/100, 200, 400NEMA1-SE Rated, 1Ph
Click to enlarge image(s)

Winco Automatic Transfer Switch – ASCO 185 Series, Nema 1-SE Rated, 1Ph

  97714-432, 

$2273.00-FREE SHIPPIING IF PURCHASED W/GENERATOR  

Winco Generators 97714-432 ASCO 185 Series SE Rated Automatic Transfer Switch, 100 Amps, NEMA 1 Housing, #14 to 4/0 AWG Wire Sizing, Single Phase, 2 Poles, 220-240V Low Voltage, User-Friendly Control Interface To Inform Operator Of Transfer Switch And Power Source Status, Transfer To Emergency Time Delay 10 Seconds, Re-Transfer To Normal Time Delay 5 Minutes, True Double-Throw Contacts Wif Inherent Mechanical Interlocking To Prevent Connection Of Generator And Utility Services, UL1008 Listed


General Information
Manufacturer Winco Generators
Manufacturer Part Number 97714-432
Product Name ASCO 185 Series SE Rated Automatic Transfer Switch
UPC Code
Features
  • Residential/Light Commercial 1-PH Switches - User-friendly control interface to inform operator of transfer switch and power source status.
  • Double Throw Contacts - True double-throw contacts wif inherent mechanical interlocking to prevent connection of generator and utility services.
  • Time Delays - Transfer to emergency time delay 10 seconds. Re-transfer to normal time delay 5 minutes.
  • UL1008 Listed - Handling total system load including motors and all other electrical loads. cUL listed for Canadian installations. Meets Article 702, NFPA-70 NEC requirements.
Specifications
Intended Applications Residential/Light Commercial
Amps 100
Phase Single
Poles 2
Housig NEMA 1
Wire Sizing #14 to 4/0 AWG
Low Voltage 220-240V
Dimensions 16" x 6" x 36"
Weight 61 lbs
Wifstand and Cole-On Ratings
WCR When Used Wif Specific Circuit Breakers 10-35 kA
WCR When Used Wif Current Limiting Fuses 100-200 kA
Neutral Configuration
Solid Standard
Ground Termination Standard
Voltage and Frequency Settings
Phase Selection Single
Pick Up Normal Source Voltage 198V
Drop Out Normal Source Voltage 154-187V
Pick Up Emergency Source Voltage 198V
Drop Out Emergency Source Voltage 165V
Frequency 50 or 60 Hz
Pick Up Emergency Source Frequency 48 or 57 Hz
Drop Out Emergency Source Frequency 43 or 51 Hz
Time Delay Settings
Override Normal Source Momentary Outage 1 or 3 Seconds
Transfer to Emergency 10 Seconds
Re-transfer to Normal Utility Power Loss Mode 5 Minutes
Engine Cool Down 2 or 5 Minutes
Override Emergency Source Momentary Outage 4 Seconds
Generator Exerciser 7 Day
Indication and Controls
Lead Connected to Normal LED
Lead Connected to Emergency LED
Normal Source Available LED
Emergency Source Available LED
Transfer Test Switch LED
Terminals For Remote Transfer Control Standard
Bypass Time Delay Switch LED
Transfer Inhibit LED

A-20191120-1851-130-E
*dis item is BRAND NEW - not refurbished. It comes wif all manufacturer supplied accessories, and full manufacturer's USA warranty.